← Back to Emergency Signs, Exit Lights & Fire Cable
Fire Resistant Cable

Emergency Signs, Exit Lights & Fire Cable

Fire Resistant Cable

FG FRC 180

Fireguard fire performance cables are designed for augmented fire resistance in applications including the delivery of power and auxiliary control in fire alarm systems, voice alarm systems, and emergency lighting systems including those applications designed to meet BS5266. These cables will form part of the requirements of BS8519 for the installation of fire resistant power and control cable systems for life safety and fire-fighting applications.

Request information

Specifications

Conductor
Solid bare copper (IEC/ EN 228, BS 6360, VDE 0295, HD 383)
Insulation
Fire resistant silicon rubber (HD 22.1, BS 7655 EI2), colors: BS7671/HD308 S2/VDE0293-308 (for more than 5 cores white core/black numbered)
Separator
Polyester tape
Drain Wire
0.80 mm Solid tinned copper
Shield
Aluminum laminated polyester tape
Sheath
HFFR, Red (RAL 3000) or White; EN 50290-2, VDE 0207 HM2, BS 7655 LTS1 / LTS3
Conductor Resistance (max.)
1 mm²: 18.1 Ω/km – 1.5 mm²: 12.1 Ω/km – 2.5 mm²: 7.41 Ω/km
Insulation Resistance (min.)
200 MΩ·km
Operating Voltage
300 V / 500 V Test Voltage 2000 V
Temperature Range
Fixed -30 °C … +90 °C Flexing -5 °C … +60 °C
Min. Bending Radius
Fixed 8 × Cable Diameter, Flexing 15 × Cable Diameter
Flame Tests
IEC / EN 60332-1, IEC 60332-3-24, (BS 4066 part 1&3), EN 50266-2-4
Insulation Integrity Smoke
IEC 60331, BS 6387 C, W, Z, EN 50200 PH30
Density
IEC / EN 61034, BS 7622, HD 606
Corrosive Gas Measurement
IEC 60754-2, BS 6425, EN 50267

Available variants

2 X 1 (RE)

Variant

Cross section 2×1 mm²

Approx. Overall Diameter
6.00 mm (±10%)
Conductor Resistance
18.1 Ω/km
Approx weight
59 kg/km

2 X 1.5 (RE)

Variant

Cross section 2×1.5 mm²

Approx. Overall Diameter
7.00 mm (±10%)
Conductor Resistance
12.1 Ω/km
Approx weight
77 kg/km

3 X 1.5 (RE)

Variant

Cross section 3×1.5 mm²

Approx. Overall Diameter
7.60 mm (±10%)
Conductor Resistance
12.1 Ω/km
Approx weight
103 kg/km

4 X 1.5 (RE)

Variant

Cross section 4×1.5 mm²

Approx. Overall Diameter
8.30 mm (±10%)
Conductor Resistance
12.1 Ω/km
Approx weight
126 kg/km

2 X 2.5 (RE)

Variant

Cross section 2×2.5 mm²

Approx. Overall Diameter
9.00 mm (±10%)
Conductor Resistance
7.41 Ω/km
Approx weight
111 kg/km

3 X 2.5 (RE)

Variant

Cross section 3×2.5 mm²

Approx. Overall Diameter
9.10 mm (±10%)
Conductor Resistance
7.41 Ω/km
Approx weight
151 kg/km

4 X 2.5 (RE)

Variant

Cross section 4×2.5 mm²

Approx. Overall Diameter
10.10 mm (±10%)
Conductor Resistance
7.41 Ω/km
Approx weight
193 kg/km

2 X 1.5 (RM)

Variant

Cross section 2×1.5 mm²

Approx. Overall Diameter
7.40 mm (±10%)
Conductor Resistance
7.41 Ω/km
Approx weight
81 kg/km

3 X 1.5 (RM)

Variant

Cross section 3×1.5 mm²

Approx. Overall Diameter
8.00 mm (±10%)
Conductor Resistance
7.41 Ω/km
Approx weight
108 kg/km

4 X 1.5 (RM)

Variant

Cross section 4×1.5 mm²

Approx. Overall Diameter
9.00 mm (±10%)
Conductor Resistance
7.41 Ω/km
Approx weight
138 kg/km

2 X 2.5 (RM)

Variant

Cross section 2×2.5 mm²

Approx. Overall Diameter
8.80 mm (±10%)
Conductor Resistance
12.1 Ω/km
Approx weight
115 kg/km

3 X 2.5 (RM)

Variant

Cross section 3×2.5 mm²

Approx. Overall Diameter
9.50 mm (±10%)
Conductor Resistance
12.1 Ω/km
Approx weight
154 kg/km

4 X 2.5 (RM)

Variant

Cross section 4×2.5 mm²

Approx. Overall Diameter
10.60 mm (±10%)
Conductor Resistance
12.1 Ω/km
Approx weight
199 kg/km

Features

  • Halogen Free Flame retardant
  • Low Smoke
  • Supplied on robust plastic reels
  • Safe & Easy to handle
  • Weather & Moisture resistant

Applications

  • Fire alarm systems
  • Voice alarm systems
  • Emergency lighting systems (BS5266)
  • Life safety and fire-fighting applications (BS8519)

Certifications

LPCB approved to BS 6387 CWZEN 50200 for 2, 3 & 4 coresLPCB Ref. No. 1788a/01